Cam Operated Rotary Switch, OFF-1-2-3 – 32A to 63A

ROTARY SWITCH

Price on request

About this item

  • 32A cam operated rotary switch with OFF, 1, 2 and 3 positions — switches a circuit off or through any one of three positions.
  • Commonly used as a phase selector for a single-phase load, or to pick one of three circuits.
  • Panel mounting: square front plate and handle in front, contacts behind.
See full description

Buying options

Price on request

Quantity
Quote

Pick the options above, or leave them and we'll suggest the right one.

Product information

Cam operated rotary switch with OFF, 1, 2 and 3 positions, 32A to 63A — for phase selection and panel switching; the 40A is rated AC-23A at 415 V.

  • Four positions — OFF, 1, 2 and 3 — marked on the front plate.
  • Cam-operated contact block behind a square front plate, turned by a large grip handle.
  • The 40A switch pictured is marked IEC 60947-3, AC-23A at 415 V, 50 Hz.
  • Its label recommends a 40A back-up fuse.
  • Terminals marked A1, A2 and A3, plus a common terminal, on the 40A unit.
  • Made for panel mounting: plate and handle in front, contacts behind.
  • A switch, not a breaker — protect the circuit with a fuse or MCB.

A cam operated rotary switch turns a handle through fixed positions; cams on the shaft open and close sets of contacts in each position. This one has four positions — OFF, 1, 2 and 3 — so a circuit can be switched off or connected through any one of three positions.

The unit pictured has terminals marked A1, A2 and A3 — a layout commonly used as a phase selector, feeding a single-phase load from any one of the three phases (R, Y or B), or to connect one supply to one of three circuits. Check the terminal diagram before wiring.

Ratings in this listing: 32A, 40A and 63A. Choose one at or above the load current and the fuse or MCB that protects the circuit; the 40A unit is marked AC-23A, the IEC 60947-3 duty for switching motors and other inductive loads.

Where to use it

  • Phase selector for single-phase loads on a three-phase supply.
  • Selecting one of three circuits, pumps or machines from one supply.
  • Control panels, pump panels and machine panels.
  • Workshops, small factories and commercial buildings.

How to install

  1. Switch off and isolate the supply before working.
  2. Cut the panel opening, fit the switch body behind the panel and the front plate and handle in front.
  3. Wire the common terminal and A1, A2, A3 as the terminal diagram shows — for phase selection, the three phases to A1, A2, A3 and the load to the common terminal.
  4. Protect the circuit with a fuse or MCB of suitable rating, then check every position before connecting the load.

Electrical work should be done by a licensed electrician. Switch heavy loads off before changing phase or circuit.

Frequently asked questions

What is a cam operated rotary switch?
A switch with a turning handle: cams on the shaft open and close contacts in each position. It is used on panels to select phases, circuits or operating modes.
What do OFF, 1, 2 and 3 mean?
OFF disconnects the circuit; 1, 2 and 3 each connect it through a different contact set (terminals A1, A2 and A3 on the unit pictured). As a phase selector, each position picks one phase — R, Y or B — for the load.
What does AC-23A mean?
AC-23A is the IEC 60947-3 utilisation category for frequently switching motor loads and other highly inductive loads — a demanding duty. The 40A switch pictured is marked AC-23A at 415 V.
Does it protect the circuit?
No. It is a switch only. Use a fuse or MCB of suitable rating ahead of it — the 40A unit label recommends a 40A back-up fuse.
Which rating do I need?
One at or above the current the load draws and the fuse or MCB that protects the circuit: 32A, 40A or 63A.

Buy cam operated rotary switches online from Electric Market, with delivery across India from our Chennai store. For panel builders, contractors and bulk orders, contact us for a quote.

SKUEM-0075
ProductCam operated rotary switch
PositionsOFF, 1, 2, 3
Rated Current32A, 40A and 63A (select option)
Marking 40a UnitIEC 60947-3, AC-23A, 415 V, 50 Hz
Back Up Fuse40A recommended on the 40A unit label
TerminalsA1, A2, A3 and a common terminal (40A unit)
MountingPanel mounting, square front plate
ProtectionNone — use a fuse or MCB
Ampere Rating32A, 40A, 63A