Four Pole (TP+N) MCB, C Curve – 20A to 32A

MCB

Price on request

About this item

  • Four pole (TP+N) C curve MCB, 20A–32A — ISI-marked to IS/IEC 60898-1, 10 kA breaking capacity, for overload and short-circuit protection.
  • ISI-marked, made to IS/IEC 60898-1.
  • 10,000 A (10 kA) rated short-circuit breaking capacity.
See full description

Buying options

Price on request

Quantity
Quote

Pick the options above, or leave them and we'll suggest the right one.

Product information

Four pole (TP+N) C curve MCB, 20A–32A — ISI-marked to IS/IEC 60898-1, 10 kA breaking capacity, for overload and short-circuit protection.

  • ISI-marked, made to IS/IEC 60898-1.
  • 10,000 A (10 kA) rated short-circuit breaking capacity.
  • C curve — suits mixed and inductive loads such as ACs, motors, pumps and fans.
  • Protects against overload (thermal) and short circuit (magnetic), with a trip-free mechanism.
  • ON/OFF contact-position window shows the state at a glance.
  • 4 modules wide; snaps onto a standard 35 mm DIN rail.
  • Made in India.

A miniature circuit breaker (MCB) switches a circuit off automatically on an overload or a short circuit, and can be switched back on once the fault is cleared — no fuse wire to replace. This Four Pole (TP+N) MCB protects the three phases of a three-phase supply and switches the neutral with them — three protected poles plus a switched neutral, marked TP+N.

The C trip curve trips instantly at 5 to 10 times the rated current, so it rides through the normal starting surge of fans, motors, pumps, ACs and LED drivers while still clearing a short circuit fast.

Ratings in this listing: 20A, 25A and 32A — choose the rating from the options.

Where to use it

  • Main switch / incomer of a three-phase home, shop or office distribution board.
  • Three-phase + neutral feeders to sub-distribution boards.
  • Isolating the neutral together with the phases for safe maintenance.

How to install

  1. Switch off the supply at the main switch before working on the board.
  2. Snap the MCB onto the 35 mm DIN rail and tighten the terminals firmly on the correct cable size.
  3. Connect the supply (line) and the load to the terminals marked on the MCB.

Electrical work should be done by a licensed electrician. For AC circuits only — solar panel and battery (DC) circuits need DC-rated MCBs.

Frequently asked questions

What does TP+N mean on a four pole MCB?
Three protected phase poles plus a neutral pole that switches with them. It protects the phases and isolates the neutral too — the usual choice for a three-phase + neutral incomer.
What is a C curve MCB?
A C curve MCB trips instantly at 5–10 times its rated current. It suits mixed and inductive loads — ACs, motors, pumps and fans — whose starting surge could nuisance-trip a B curve MCB.
What does 10 kA breaking capacity mean?
The MCB can safely interrupt a short-circuit current of up to 10,000 amperes — a comfortable margin for homes, shops and offices.
Which MCB rating do I need?
Typically 6A–10A for lights and fans, 16A for socket circuits and geysers up to 3 kW, 16A–20A for a 1.5 ton AC, 20A–25A for a 2 ton AC, 32A for sub-mains, and 40A–63A for main incomers. The MCB must never be rated above what the cable can carry.
Is an MCB the same as an isolator or RCCB?
No. An MCB trips on overload and short circuit. An isolator only switches the supply on and off and does not trip. An RCCB trips on earth leakage to protect people from electric shock — homes need one of 30 mA or less in addition to MCBs.
Why does an MCB trip more often on hot days?
MCBs are calibrated at 30 °C. In a hot distribution board they carry slightly less current, so keep some margin between the running load and the rating — but never fit a bigger MCB than the cable allows.

Buy ISI-marked four pole C curve MCBs online from Electric Market, with delivery across India from our Chennai store. For panel builders, contractors and bulk orders, contact us for a quote.

SKUEM-0011-LEGR-32AF
ProductMiniature circuit breaker, Four Pole (TP+N)
Trip CurveC (magnetic trip at 5–10 × rated current)
Rated Current20A, 25A and 32A
Rated Voltage400 V AC, 50 Hz (three-phase + neutral)
Breaking Capacity10,000 A (10 kA)
StandardIS/IEC 60898-1, ISI marked
Width4 modules (4 × about 18 mm)
Mounting35 mm DIN rail
IndicationON/OFF contact-position window
Ampere Rating20A, 25A, 32A
No Of PolesTPN, FP
Tripping CurveC Curve